VICKERS® 25V REPLACEMENT VANE PUMPS

  • Low Noise Characteristics
  • 12 Vane Systems - Low Amplitude Flow Pulsations
  • Long Life
  • Inlet and outlet ports can be oriented in four different positions relative to each other
Image Item
Code
Description Unit
Price
Unit Order
Qty.
Stock
Status
6301098 25V12A1A22R Vickers Replacement. Hydraulic pump fixed vane 2.47 in3 displacement. Mount is standard SAE-B 2-bolt flange. 7/8" round X 3/16" keyed X 2.32" long shaft (includes pilot length). Pilot diameter is 4.00". 2500 psi maximum, 1800 RPM maximum, CW rotation. #24 code 61 inlet, #16 code 61 outlet. Outlet is on opposite side of the inlet when viewed from the cover end of the pump. Item usually ships in 1-2 days. Replaces Vickers 25V12A1A22R. $478.80 EACH In Stock
6301099 25V14A1A22R Vickers Replacement. Hydraulic pump fixed vane 2.78 in3 displacement. Mount is standard SAE-B 2-bolt flange. 7/8" round X 3/16" keyed X 2.32" long shaft (includes pilot length). Pilot diameter is 4.00". 2500 psi maximum, 1800 RPM maximum, CW rotation. #24 code 61 inlet, #16 code 61 outlet. Outlet is on opposite side of the inlet when viewed from the cover end of the pump. Item usually ships in 1-2 days. Replaces Vickers 25V14A1A22R. $478.80 EACH In Stock
6301100 25V17A1A22R Vickers Replacement. Hydraulic pump fixed vane 3.39 in3 displacement. Mount is standard SAE-B 2-bolt flange. 7/8" round X 3/16" keyed X 2.32" long shaft (includes pilot length). Pilot diameter is 4.00". 2500 psi maximum, 1800 RPM maximum, CW rotation. #24 code 61 inlet, #16 code 61 outlet. Outlet is on opposite side of the inlet when viewed from the cover end of the pump. Item usually ships in 1-2 days. Replaces Vickers 25V17A1A22R. $478.80 EACH In Stock
6301101 25V21A1A22R Vickers Replacement. Hydraulic pump fixed vane 4.13 in3 displacement. Mount is standard SAE-B 2-bolt flange. 7/8" round X 3/16" keyed X 2.32" long shaft (includes pilot length). Pilot diameter is 4.00". 2500 psi maximum, 1800 RPM maximum, CW rotation. #24 code 61 inlet, #16 code 61 outlet. Outlet is on opposite side of the inlet when viewed from the cover end of the pump. Item usually ships in 1-2 days. Replaces Vickers 25V21A1A22R. $478.80 EACH In Stock
6301103 25V12A1A22L Vickers Replacement. Hydraulic pump fixed vane 2.47 in3 displacement. Mount is standard SAE-B 2-bolt flange. 7/8" round X 3/16" keyed X 2.32" long shaft (includes pilot length). Pilot diameter is 4.00". 2500 psi maximum, 1800 RPM maximum, CCW rotation. #24 code 61 inlet, #16 code 61 outlet. Outlet is on opposite side of the inlet when viewed from the cover end of the pump. Item usually ships in 1-2 days. Replaces Vickers 25V12A1A22L. $478.80 EACH In Stock
6301104 25V14A1A22L Vickers Replacement. Hydraulic pump fixed vane 2.78 in3 displacement. Mount is standard SAE-B 2-bolt flange. 7/8" round X 3/16" keyed X 2.32" long shaft (includes pilot length). Pilot diameter is 4.00". 2500 psi maximum, 1800 RPM maximum, CCW rotation. #24 code 61 inlet, #16 code 61 outlet. Outlet is on opposite side of the inlet when viewed from the cover end of the pump. Item usually ships in 1-2 days. Replaces Vickers 25V14A1A22L. $478.80 EACH In Stock
6301105 25V17A1A22L Vickers Replacement. Hydraulic pump fixed vane 3.39 in3 displacement. Mount is standard SAE-B 2-bolt flange. 7/8" round X 3/16" keyed X 2.32" long shaft (includes pilot length). Pilot diameter is 4.00". 2500 psi maximum, 1800 RPM maximum, CCW rotation. #24 code 61 inlet, #16 code 61 outlet. Outlet is on opposite side of the inlet when viewed from the cover end of the pump. Item usually ships in 1-2 days. Replaces Vickers 25V17A1A22L. $478.80 EACH In Stock
6301106 25V21A1A22L Vickers Replacement. Hydraulic pump fixed vane 4.13 in3 displacement. Mount is standard SAE-B 2-bolt flange. 7/8" round X 3/16" keyed X 2.32" long shaft (includes pilot length). Pilot diameter is 4.00". 2500 psi maximum, 1800 RPM maximum, CCW rotation. #24 code 61 inlet, #16 code 61 outlet. Outlet is on opposite side of the inlet when viewed from the cover end of the pump. Item usually ships in 1-2 days. Replaces Vickers 25V21A1A22L. $478.80 EACH In Stock
6301108 25V12A11A22R Vickers Replacement. Hydraulic pump fixed vane 2.47 in3 displacement. Mount is standard SAE-B 2-bolt flange. 7/8"-13 spline X 1.75" long shaft (includes pilot length). Pilot diameter is 4.00". 2500 psi maximum, 1800 RPM maximum, CW rotation. #24 code 61 inlet, #16 code 61 outlet. Outlet is on opposite side of the inlet when viewed from the cover end of the pump. Item usually ships in 1-2 days. Replaces Vickers 25V12A11A22R. $478.80 EACH In Stock
6301109 25V14A11A22R Vickers Replacement. Hydraulic pump fixed vane 2.78 in3 displacement. Mount is standard SAE-B 2-bolt flange. 7/8"-13 spline X 1.75" long shaft (includes pilot length). Pilot diameter is 4.00". 2500 psi maximum, 1800 RPM maximum, CW rotation. #24 code 61 inlet, #16 code 61 outlet. Outlet is on opposite side of the inlet when viewed from the cover end of the pump. Item usually ships in 1-2 days. Replaces Vickers 25V14A11A22R. $478.80 EACH In Stock
6301110 25V17A11A22R Vickers Replacement. Hydraulic pump fixed vane 3.39 in3 displacement. Mount is standard SAE-B 2-bolt flange. 7/8"-13 spline X 1.75" long shaft (includes pilot length). Pilot diameter is 4.00". 2500 psi maximum, 1800 RPM maximum, CW rotation. #24 code 61 inlet, #16 code 61 outlet. Outlet is on opposite side of the inlet when viewed from the cover end of the pump. Item usually ships in 1-2 days. Replaces Vickers 25V17A11A22R. $478.80 EACH In Stock
6301111 25V21A11A22R Vickers Replacement. Hydraulic pump fixed vane 4.13 in3 displacement. Mount is standard SAE-B 2-bolt flange. 7/8"-13 spline X 1.75" long shaft (includes pilot length). Pilot diameter is 4.00". 2500 psi maximum, 1800 RPM maximum, CW rotation. #24 code 61 inlet, #16 code 61 outlet. Outlet is on opposite side of the inlet when viewed from the cover end of the pump. Item usually ships in 1-2 days. Replaces Vickers 25V21A11A22R. $478.80 EACH In Stock
6301113 25V12A11A22L Vickers Replacement. Hydraulic pump fixed vane 2.47 in3 displacement. Mount is standard SAE-B 2-bolt flange. 7/8"-13 spline X 1.75" long shaft (includes pilot length). Pilot diameter is 4.00". 2500 psi maximum, 1800 RPM maximum, CCW rotation. #24 code 61 inlet, #16 code 61 outlet. Outlet is on opposite side of the inlet when viewed from the cover end of the pump. Item usually ships in 1-2 days. Replaces Vickers 25V12A11A22L. $478.80 EACH In Stock
6301114 25V14A11A22L Vickers Replacement. Hydraulic pump fixed vane 2.78 in3 displacement. Mount is standard SAE-B 2-bolt flange. 7/8"-13 spline X 1.75" long shaft (includes pilot length). Pilot diameter is 4.00". 2500 psi maximum, 1800 RPM maximum, CCW rotation. #24 code 61 inlet, #16 code 61 outlet. Outlet is on opposite side of the inlet when viewed from the cover end of the pump. Item usually ships in 1-2 days. Replaces Vickers 25V14A11A22L. $478.80 EACH In Stock
6301115 25V17A11A22L Vickers Replacement. Hydraulic pump fixed vane 3.39 in3 displacement. Mount is standard SAE-B 2-bolt flange. 7/8"-13 spline X 1.75" long shaft (includes pilot length). Pilot diameter is 4.00". 2500 psi maximum, 1800 RPM maximum, CCW rotation. #24 code 61 inlet, #16 code 61 outlet. Outlet is on opposite side of the inlet when viewed from the cover end of the pump. Item usually ships in 1-2 days. Replaces Vickers 25V17A11A22L. $478.80 EACH In Stock
   Page 1 of 5