• 9 gpm at 3000 psi maximum • #6 SAE
o-ring ports (9/16-18) |
This dual sequence valve automatically controls the
sequencing of two cylinders. This sequencing is
controlled both on extension and retraction.
Sequencing pressure point is adjustable. Automatic
sequence: Cylinder #1 extends all the way out. Then
cylinder #2 begins to extend. Cylinder #2 extends
all the way out. |
When we want to retract the two cylinders, cylinder
#2 retracts all the way. Then cylinder #1 begins to
retract. Cylinder #1 retracts all the way back. This
circuit works well on a double hinged (2 cylinder
controlled) arm. Examples are wings on an
agricultural implement or a position then clamp
circuit.
▼
Click HS number for price |